summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorRajesh Bharathwaj <rabharat@qti.qualcomm.com>2022-07-11 19:33:53 -0700
committerRajesh Bharathwaj <rabharat@qti.qualcomm.com>2022-07-26 16:32:04 -0700
commitebaded9723f00ac1cd546a9011b997c1cc734be8 (patch)
treec509e1b1223ec8938b6f75da2cf69ce351be76de
parent31a79401a7cb46332529fe007be57fd7fc733734 (diff)
downloaddevicetree-ebaded9723f00ac1cd546a9011b997c1cc734be8.tar.gz
ARM: dts: msm: Change the typical voltage for XR Reference devices
Typical voltage for XR Reference devices is 5.7V and Min. voltage is 5.6V Most of the devices work with minimum range but few devices not work when reboot is issued repeatedly. So, changing the minimum voltage to typical fixes the issue. Change-Id: I9d16862bd84e56e81075be8c896f91594107ca4d
-rw-r--r--qcom/kona-xrfusion-ult.dtsi8
-rw-r--r--qcom/kona-xrsku4.dtsi8
2 files changed, 16 insertions, 0 deletions
diff --git a/qcom/kona-xrfusion-ult.dtsi b/qcom/kona-xrfusion-ult.dtsi
index d9c69782..61155ebf 100644
--- a/qcom/kona-xrfusion-ult.dtsi
+++ b/qcom/kona-xrfusion-ult.dtsi
@@ -887,6 +887,14 @@
};
&dsi_panel_pwr_supply_lab_ibb {
+ qcom,panel-supply-entry@1 {
+ qcom,supply-min-voltage = <5700000>;
+ };
+
+ qcom,panel-supply-entry@2 {
+ qcom,supply-min-voltage = <5700000>;
+ };
+
qcom,panel-supply-entry@3 {
reg = <1>;
qcom,supply-name = "avdd";
diff --git a/qcom/kona-xrsku4.dtsi b/qcom/kona-xrsku4.dtsi
index 8099ea83..f6089491 100644
--- a/qcom/kona-xrsku4.dtsi
+++ b/qcom/kona-xrsku4.dtsi
@@ -999,6 +999,14 @@
};
&dsi_panel_pwr_supply_lab_ibb {
+ qcom,panel-supply-entry@1 {
+ qcom,supply-min-voltage = <5700000>;
+ };
+
+ qcom,panel-supply-entry@2 {
+ qcom,supply-min-voltage = <5700000>;
+ };
+
qcom,panel-supply-entry@3 {
reg = <1>;
qcom,supply-name = "avdd";